Part Nr: 12-0231
|
System |
|
|
Data transfer |
EasyLinkTM Windows® program |
|
Measurement distance |
20m [66 feet] |
|
Temperature range |
32-122° F [0-50° C] |
|
Relative humidity |
10-95% |
|
Max. displayed error |
±1% +1 digit |
|
Weight complete system |
12 kg [27 lbs] |
|
Carrying case |
W×H×D 480×340×180 mm [19×14×7"] |
|
Measuring units (S, M) |
|
|
Type of laser |
Diode laser |
|
Laser wavelength |
Class 2 |
|
Laser output power |
< 1 mW |
|
Resolution |
0,001 mm [0.05 mils] |
|
Type of detectors |
18 mm sq PSD [0.71" sq] |
|
Spirit vials |
Resolution 0.5° |
|
Inclinometers |
Electronic inclinometers, 0.1° resolution |
|
Thermal sensors |
± 1° C accuracy |
|
Protection |
No influence from ambient light |
|
Housing material |
Anodized aluminum |
|
Dimensions |
W×H×D: 60×60×50 mm [2.36×2.36×1.97"] |
|
Weight |
198 g [7 oz] |
|
Display unit D279 |
|
|
Measurement programs |
27 programs |
|
Type of display |
Backlit dot matrix LCD |
|
Display size |
73×73 mm [2.87×2.87"] |
|
Displayed resolution |
Changeable; 0.1, 0.01, 0.001mm. 5, 0.5, 0.05 mils/thou |
|
Battery |
4 × 1.5 V R14 (C) |
|
Operating time |
24-48 hours depending on connected equipment |
|
Output port |
RS232 for printer and PC communication |
|
Keyboard |
Membrane alphanumeric multi function |
|
Memory |
Storage for e.g. 1000 shaft alignments |
|
Settings |
e.g. Value filtering, Measuring unit (mil/thou/mm) |
|
Housing material |
Anodized aluminum / ABS-plastics |
|
Dimensions |
W×H×D: 180×175×40 mm [7"×6 7/8"×1 9/16"] |
|
Weight |
1100 g [2.4 lbs] |
|
Leatherette |
|
|
For the display unit. With suspension belt. |
|
Shaft brackets |
|
|
Fixture |
V-fixture for chain |
|
Material |
Anodized aluminum |
|
Shaft diameter |
Ø 20-450 mm [3/4"-18"] with standard chains. |
|
Magnet bases |
|
|
Holding power |
800 N |
|
Rods |
|
|
Material |
Stainless steel |
|
Length |
60 and 240 mm [2.36" and 9.44"] |
|
Cables |
|
|
Type |
With Push/Pull connection |
|
Length |
2 m [78.74"] |